Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Heart ; 109(12): 944-950, 2023 05 26.
Artículo en Inglés | MEDLINE | ID: mdl-36657962

RESUMEN

OBJECTIVE: Current guidelines recommend use of heart valve centres (HVCs) to deliver optimal quality of care for patients with valve disease but there is no evidence to support this. The hypothesis of this study is that patient care with severe aortic stenosis (AS) will differ in HVCs compared with satellite centres. We aimed to compare the treatment of patients with AS at HVCs (tertiary care hospitals with full access to AS interventions) to satellites (hospitals without such access). METHODS: IMPULSE enhanced is a European, observational, prospective registry enrolling consecutive patients with newly diagnosed severe AS at four HVCs and 10 satellites. Clinical characteristics, interventions performed and outcomes up to 1 year by site-type were examined. RESULTS: Among 790 patients, 594 were recruited in HVCs and 196 in satellites. At baseline, patients in HVCs had more severe valve disease (higher peak aortic velocity (4.3 vs 4.1 m/s; p=0.008)) and greater comorbidity (coronary artery disease (CAD) (44% vs 27%; p<0.001) prior myocardial infarction (MI) (11% vs 5.1%; p=0.011) and chronic pulmonary disease (17% vs 8.9%; p=0.007)) than those presenting in satellites. An aortic valve replacement was performed more often by month 3 in HVCs than satellites in the overall population (52.6% of vs 31.3%; p<0.001) and in symptomatic patients (66.7% vs 43.2%, p<0.001). One-year survival rate was higher for patients in HVCs than satellites (HR2.19; 95% CI 1.28 to 3.73 total population and 2.89 (95%CI 1.64 to 5.11) for symptomatic patients. CONCLUSIONS: Our data support the implementation of referral pathways that direct patients to HVCs performing both surgery and transcatheter interventions. TRIAL REGISTRATION NUMBER: NCT03112629.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Centros de Atención Secundaria , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Factores de Riesgo
2.
Circulation ; 141(19): 1527-1537, 2020 05 12.
Artículo en Inglés | MEDLINE | ID: mdl-32272848

RESUMEN

BACKGROUND: This study aimed to compare echocardiographic findings in low-risk patients with severe aortic stenosis after surgical aortic valve replacement (SAVR) or transcatheter aortic valve replacement (TAVR). METHODS: The PARTNER 3 trial (Placement of Aortic Transcatheter Valves) randomized 1000 patients with severe aortic stenosis and low surgical risk to undergo either transfemoral TAVR with the balloon-expandable SAPIEN 3 valve or SAVR. Transthoracic echocardiograms obtained at baseline and at 30 days and 1 year after the procedure were analyzed by a consortium of 2 echocardiography core laboratories. RESULTS: The percentage of moderate or severe aortic regurgitation (AR) was low and not statistically different between the TAVR and SAVR groups at 30 days (0.8% versus 0.2%; P=0.38). Mild AR was more frequent after TAVR than SAVR at 30 days (28.8% versus 4.2%; P<0.001). At 1 year, mean transvalvular gradient (13.7±5.6 versus 11.6±5.0 mm Hg; P=0.12) and aortic valve area (1.72±0.37 versus 1.76±0.42 cm2; P=0.12) were similar in TAVR and SAVR. The percentage of severe prosthesis-patient mismatch at 30 days was low and similar between TAVR and SAVR (4.6 versus 6.3%; P=0.30). Valvulo-arterial impedance (Zva), which reflects total left ventricular hemodynamic burden, was lower with TAVR than SAVR at 1 year (3.7±0.8 versus 3.9±0.9 mm Hg/mL/m2; P<0.001). Tricuspid annulus plane systolic excursion decreased and the percentage of moderate or severe tricuspid regurgitation increased from baseline to 1 year in SAVR but remained unchanged in TAVR. Irrespective of treatment arm, high Zva and low tricuspid annulus plane systolic excursion, but not moderate to severe AR or severe prosthesis-patient mismatch, were associated with increased risk of the composite end point of mortality, stroke, and rehospitalization at 1 year. CONCLUSIONS: In patients with severe aortic stenosis and low surgical risk, TAVR with the SAPIEN 3 valve was associated with similar percentage of moderate or severe AR compared with SAVR but higher percentage of mild AR. Transprosthetic gradients, valve areas, percentage of severe prosthesis-patient mismatch, and left ventricular mass regression were similar in TAVR and SAVR. SAVR was associated with significant deterioration of right ventricular systolic function and greater tricuspid regurgitation, which persisted at 1 year. High Zva and low tricuspid annulus plane systolic excursion were associated with worse outcome at 1 year whereas AR and severe prosthesis-patient mismatch were not. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02675114.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Ecocardiografía , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica , Humanos , Masculino , América del Norte , Valor Predictivo de las Pruebas , Diseño de Prótesis , Falla de Prótesis , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
3.
J Am Coll Cardiol ; 74(21): 2638-2651, 2019 11 26.
Artículo en Inglés | MEDLINE | ID: mdl-31753206

RESUMEN

The prevalence of calcific aortic stenosis (AS) and of cardiac amyloidosis (CA) increases with age, and their association is not uncommon in the elderly. The identification of CA is particularly challenging in patients with AS because these 2 conditions share several features. It is estimated that ≤15% of the AS population and ≤30% of the subset with low-flow, low-gradient pattern may have CA. In patients with AS, CA is associated with increased risk of heart failure, mortality, and treatment futility with aortic valve replacement. In case of suspicion of CA, it is thus crucial to confirm the diagnosis to guide therapeutic management of AS and eventually implement recently developed pharmacological treatment dedicated to transthyretin amyloidosis. Given the high surgical risk of patients with AS and concomitant CA, transcatheter aortic valve replacement may be preferred to surgery in these patients.


Asunto(s)
Amiloidosis/complicaciones , Estenosis de la Válvula Aórtica/complicaciones , Válvula Aórtica/patología , Calcinosis/complicaciones , Amiloidosis/diagnóstico por imagen , Amiloidosis/epidemiología , Amiloidosis/terapia , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/terapia , Calcinosis/diagnóstico por imagen , Calcinosis/terapia , Humanos , Prevalencia
4.
Can J Cardiol ; 35(9): 1195-1207, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31472817

RESUMEN

Valvular heart calcification is common in patients with chronic kidney disease (CKD), especially in those receiving hemodialysis therapy, and it is associated with poor prognosis. Furthermore, progression of valvular heart disease (VHD) and structural valve deterioration of bioprosthetic valves are faster in these patients. Mechanisms involved in the pathophysiology of VHD are similar between patients with and without impaired kidney function, but CKD is associated with a bone metabolism dysregulation, which might lead to a procalcifying phenotype within vessels and heart valves. CKD is also associated with left ventricular remodelling and dysfunction, which might contribute to increase the risk of heart failure and death in patients with VHD. Even if promising pharmacotherapeutic avenues are in development, no medical treatment can prevent or reduce the valvular calcific process. Patients with advanced CKD should undergo transthoracic echocardiography for detection of VHD, and if present, follow-up should be more frequent than what is recommended in the guidelines. Transcatheter valve replacement might be preferred over surgical replacement in patients with CKD and severe aortic valve stenosis.


Asunto(s)
Calcinosis/complicaciones , Tasa de Filtración Glomerular/fisiología , Enfermedades de las Válvulas Cardíacas/etiología , Insuficiencia Renal Crónica/complicaciones , Remodelación Ventricular/fisiología , Ecocardiografía , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/fisiopatología , Humanos , Insuficiencia Renal Crónica/fisiopatología
5.
Open Heart ; 6(2): e001019, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31413844

RESUMEN

Background: Severe aortic stenosis (AS) is one of the most common and most serious valve diseases. Without timely intervention with surgical aortic valve replacement or transcatheter aortic valve replacement, patients have an estimated survival of 2-3 years. Guidelines for the treatment of AS have been developed, but studies suggest that as many as 42% of patients with AS are not treated according to these recommendations.The aims of this registry are to delineate the caseload of patients with AS, outline the management of these patients and determine appropriateness of treatments in participating centres with and without onsite access to surgery and percutaneous treatments. Methods/design: The IMPULSE enhanced registry is an international, multicentre, prospective, observational cohort registry conducted at four central full access centres (tertiary care hospitals) and at least two satellite centres per hub (primary/secondary care hospitals). An estimated 800 patients will be enrolled in the registry and patient follow-up will last for 12 months. Discussion: In addition to the primary aims determining the caseload management and outcome of patients with AS in primary, secondary and tertiary care settings, the registry will also determine a time course for the transition from asymptomatic to symptomatic status and the diagnostic steps, treatment decisions and the identification of decision-makers in tertiary versus primary/secondary care hospitals. The last patient will be enrolled in the registry in 2018 and results of the registry are anticipated in 2019. Registration number: NCT03112629.

7.
Arch Cardiovasc Dis ; 106(2): 111-5, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23527915

RESUMEN

Although mitral stenosis is mostly due to rheumatic fever, other etiologies, such as degenerative, congenital, drug- or radiotherapy-induced mitral stenosis, are emerging and need to be recognized in order to decide the best therapeutic options. This pictorial review describes the echocardiographic features of these different anatomical types and the additional value of three-dimensional echocardiography.


Asunto(s)
Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Estenosis de la Válvula Mitral/diagnóstico por imagen , Válvula Mitral/diagnóstico por imagen , Traumatismos por Radiación/diagnóstico por imagen , Cardiopatía Reumática/diagnóstico por imagen , Humanos , Estenosis de la Válvula Mitral/congénito , Valor Predictivo de las Pruebas , Pronóstico , Factores de Riesgo
8.
Eur J Cardiothorac Surg ; 41(4): 800-5, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22219468

RESUMEN

OBJECTIVES: We previously reported a possible but unusual prosthetic-valve infective endocarditis (PV-IE) occurring on a Cryolife O'Brien Stentless Porcine Xenograft (CLOB) (anatomic damages suggestive of IE but negative inflammatory and microbiological markers). We reviewed all cases of aortic PV-IE admitted in our institution and compared the clinical presentation, bacteriological and echocardiographic features according to the type of prosthesis. METHODS: Sixty consecutive cases with possible or definite aortic PV-IE (23 CLOB, 26 mechanical valve and 11 stented bioprosthesis) were admitted between 2002 and 2008. RESULTS: Patients with CLOB had more prosthetic dehiscence (P = 0.006) and severe regurgitation (P = 0.01) than those with mechanical or stented prosthetic valves. In contrast, they had less fever (P = 0.003), lower C-reactive protein (CRP) levels (P = 0.02) and more frequently negative blood cultures (P = 0.08). Differences were due to seven patients who presented with no fever, low CRP, negative blood culture, negative valve culture and PCR when performed, despite echocardiographic features suggestive of IE (abscess or valve dehiscence). All were first operated on since 2004 when the manufacturing process changed and required a second surgery. The French Authority of Health was informed leading to the withdrawal of the CLOB from the market in 2010. CONCLUSIONS: One-third of patients with CLOB admitted for possible or definite PV-IE presented with anatomic damages suggestive of IE but with negative inflammatory and microbiological markers. The exact aetiology remains unclear, but the present data have led to the worldwide withdrawal of prosthesis in 2010. A close follow-up of patients implanted with CLOB should be advised, especially if it has been manufactured since 2004.


Asunto(s)
Válvula Aórtica/cirugía , Bioprótesis , Endocarditis/diagnóstico , Prótesis Valvulares Cardíacas , Infecciones Relacionadas con Prótesis/diagnóstico , Anciano , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/etiología , Biomarcadores/sangre , Proteína C-Reactiva/análisis , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Falla de Prótesis , Stents
9.
Circulation ; 125(2): 226-32, 2012 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-22133496

RESUMEN

BACKGROUND: Optimal management, including timing of surgery, remains debated in Marfan syndrome because of a lack of data on aortic risk associated with this disease. METHODS AND RESULTS: We used our database to evaluate aortic risk associated with standardized care. Patients who fulfilled the international criteria, had not had previous aortic surgery or dissection, and came to our center at least twice were included. Aortic measurements were made with echocardiography (every 2 years); patients were given systematic ß-blockade and advice about sports activities. Prophylactic aortic surgery was proposed when the maximal aortic diameter reached 50 mm. Seven hundred thirty-two patients with Marfan syndrome were followed up for a mean of 6.6 years. Five deaths and 2 dissections of the ascending aorta occurred during follow-up. Event rate (death/aortic dissection) was 0.17%/y. Risk rose with increasing aortic diameter measured within 2 years of the event: from 0.09%/y per year (95% confidence interval, 0.00-0.20) when the aortic diameter was <40 mm to 0.3% (95% confidence interval, 0.00-0.71) with diameters of 45 to 49 mm and 1.33% (95% confidence interval, 0.00-3.93) with diameters of 50 to 54 mm. The risk increased 4 times at diameters ≥50 mm. The annual risk dropped below 0.05% when the aortic diameter was <50 mm after exclusion of a neonatal patient, a woman who became pregnant against our recommendation, and a 72-year-old woman with previous myocardial infarction. CONCLUSIONS: Risk of sudden death or aortic dissection remains low in patients with Marfan syndrome and aortic diameter between 45 and 49 mm. Aortic diameter of 50 mm appears to be a reasonable threshold for prophylactic surgery.


Asunto(s)
Enfermedades de la Aorta/epidemiología , Síndrome de Marfan/epidemiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Disección Aórtica , Aorta/patología , Aneurisma de la Aorta , Enfermedades de la Aorta/etiología , Enfermedades de la Aorta/patología , Niño , Preescolar , Estudios de Cohortes , Ecocardiografía , Femenino , Estudios de Seguimiento , Humanos , Lactante , Recién Nacido , Masculino , Síndrome de Marfan/mortalidad , Síndrome de Marfan/cirugía , Persona de Mediana Edad , Adulto Joven
10.
Eur Heart J Cardiovasc Imaging ; 13(7): 574-8, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22127623

RESUMEN

AIMS: Patients with acute myocardial infarction (AMI) represent a high-risk population in which screening for abdominal aortic aneurysm (AAA) is recommended but only occasionally performed. Transthoracic echocardiography (TTE) may offer the unique opportunity to evaluate the cardiac function and to screen for AAA during the same examination. We aimed to evaluate the feasibility of AAA screening at bedside using a portable cardiac ultrasound (US) echo machine and to determine the prevalence of AAA in population with AMI. METHODS AND RESULTS: The AA diameter was measured at bedside at the end of a regular TTE performed in consecutive patients admitted for AMI in the coronary care unit using a portable echo machine (Vividi, General Electric). AAA was defined by a transverse diameter of ≥ 30 mm. We prospectively enrolled 193 patients (65 ± 11 years, 77% male). Measurement of the AA diameter was feasible in 93% and the duration was 3 ± 1 min. An AAA was observed in nine patients (4.7%) and the prevalence increased with age (7.7% after 60 years and 9.2% after 65 years). No AAA was observed in patients under 50 years old. Inter-observer variability between cardiologists using the portable US system was excellent (mean difference 1.8 ± 2.0 mm) as well as the accuracy compared with measurements performed by a radiologist using a dedicated vascular US system (mean difference 1.5 ± 1.3 mm). CONCLUSION: Overall, the prevalence of AAA was 4.7%, increased with age, and seems higher than expected in the 'same-aged population'. In regard to the simplicity, accuracy, and feasibility, screening for AAA during TTE (one cardiovascular shot) may be of value after AMI especially in elderly patients.


Asunto(s)
Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Unidades de Cuidados Coronarios , Ecocardiografía/instrumentación , Tamizaje Masivo , Infarto del Miocardio/complicaciones , Sistemas de Atención de Punto , Anciano , Aneurisma de la Aorta Abdominal/epidemiología , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Estudios Prospectivos , Reproducibilidad de los Resultados , Medición de Riesgo , Factores de Riesgo
11.
Heart ; 98(3): 195-201, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21948959

RESUMEN

BACKGROUND: Rate control and rhythm control are accepted management strategies for atrial fibrillation (AF). OBJECTIVE: RealiseAF aimed to describe the success of either strategy and the impact of control on symptomatic status of patients with AF. METHODS: This international, observational, cross-sectional survey of patients with any history of AF in the previous year, recorded AF characteristics, management and frequency of control (defined as sinus rhythm or AF with resting heart rate ≤80 bpm). RESULTS: Overall, 9665 patients were evaluable for AF control, with 59.0% controlled (sinus rhythm 26.5%, AF ≤80 bpm 32.5%) and 41.0% uncontrolled. Symptom prevalence in the previous week was lower in controlled than uncontrolled AF (55.7% vs 68.4%; p<0.001) and similar for patients in sinus rhythm versus AF ≤80 bpm (54.8% vs 56.4%; p=0.23). At the visit, AF-related functional impairment (EHRA class >I) was seen in 67.4% of patients with controlled AF and 82.1% of patients with uncontrolled AF (p<0.001). Quality-of-life (QoL, measured using EQ-5D) was better for patients with controlled versus uncontrolled AF using the Visual Analogue Scale (mean (SD) score 67.1 (18.4) vs 63.2 (18.9); p<0.001), single index utility score (median 0.78 vs 0.73; p<0.001), or five dimensions of well-being (all p<0.001). Irrespective of AF control, cardiovascular events had led to hospitalisation in the past year in 28.1%. CONCLUSION: AF control is not optimal. Control appears to be associated with fewer symptoms and better QoL, but even patients with controlled AF have frequent symptoms, functional impairment, altered QoL and cardiovascular events. New treatments are needed to improve control and minimise the functional and QoL burden of AF.


Asunto(s)
Fibrilación Atrial/psicología , Terapia de Resincronización Cardíaca/métodos , Frecuencia Cardíaca/fisiología , Calidad de Vida , Sistema de Registros , Anciano , Fibrilación Atrial/epidemiología , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/terapia , Estudios Transversales , Femenino , Estudios de Seguimiento , Salud Global , Hospitalización/estadística & datos numéricos , Humanos , Masculino , Prevalencia , Pronóstico , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
12.
J Heart Valve Dis ; 20(6): 627-32, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22655492

RESUMEN

BACKGROUND AND AIM OF THE STUDY: In patients with mitral stenosis (MS), previous studies have shown discordant results with regards to improvements in right ventricular (RV) function immediately after percutaneous mitral commissurotomy (PMC). Hence, the study aim was to evaluate the impact of PMC on RV function, by using Doppler-echocardiography. METHODS: A total of 41 patients with severe symptomatic MS, in sinus rhythm, who had been referred to the authors' institution for PMC, was prospectively enrolled. A group of 25 healthy age- and gender-matched subjects served as controls. Transthoracic echocardiography (TTE) was performed on the day before and at 24/48 h after PMC. The RV function was evaluated using the Tricuspid Annular Plane Excursion (TAPSE), the RV Tei index, and systolic myocardial velocities by Doppler tissue imaging peak isovolumic contraction (DTI(IVC)) and peak systolic (DTI(S)) at the lateral tricuspid annulus). RESULTS: All patients but three underwent a successful PMC. The mitral valve area (MVA) was significantly increased (1.8 +/- 0.3 versus 1.1 +/- 0.2 cm2, p <0.0001), while the mean gradient (5 +/- 2 versus 10 +/- 7 mmHg, p <0.0001) and systolic pulmonary artery pressure (40 +/- 10 versus 54 +/- 21 mmHg, p = 0.0002) were decreased. Compared to healthy controls, the RV dysfunction in MS patients was authenticated by the DTI(IVC) and the Tei index (8.4 +/- 3.0 versus 11.1 +/- 2.1 cm/s, p = 0.0002 and 0.33 +/- 0.10 versus 0.18 +/- 0.10 respectively, p <0.0001), but not by DTI(S) (12.9 +/- 3 versus 12.3 +/- 1.5 cm/s, p = 0.35) or TAPSE (24 +/- 5 versus 23 +/- 3 mm, p = 0.50). After PMC, no significant change regarding RV function was observed (TAPSE: 24 +/- 5 versus 24 +/- 5 mm, p = 0.54; Tei Index: 0.33 +/- 0.10 versus 0.36 +/- 0.12, p = 0.20; DTI(IVC): 8.4 +/- 3.0 versus 9.2 +/- 3.4 cm/s, p = 0.08 and DTI(S): 12.9 +/- 3.0 versus 13.0 +/- 3.4 cm/s, p = 0.54). CONCLUSION: The DTI(IVC) and Tei index appear to serve as the more sensitive indices of RV dysfunction in patients with MS. Immediately after a successful PMC, no significant change in Doppler echocardiographic parameters of RV function was observed. Whether late improvement in RV function can be observed, and the prognostic value of these parameters realized, deserve further investigation.


Asunto(s)
Cateterismo , Estenosis de la Válvula Mitral/terapia , Función Ventricular Derecha , Adulto , Anciano , Estudios de Casos y Controles , Ecocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...